M-03 | E.P.A. EXAM
M-03 | E.P.A. CERTIFICATION EXAM PREPARATION
LEARN: THE TRANSITION AND RECOVERY OF REFRIGERANTS FOR THE E.P.A SECTION 608
With this course we will prepare you to pass the Certification Exam, Section 608, for the E.P.A (Environmental Protection Agency). This universal license is a requirement by the Federal Government in accordance with the Clean Air Act, which approves technicians to perform service and maintenance procedures for systems of air conditioning and refrigeration. You will receive hands-on labs in recovery, pressurization, and handling of the refrigerants.
M-03 | PREPARACIÓN DEL EXAMEN DE CERTIFICACIÓN E.P.A.
APRENDA : LA TRANSICIÓN Y RECUPERACIÓN DE REFRIGERANTES PARA LA EPA SECCIÓN 608
Con este curso se preparará para pasar el examen de certificación de la Sección 608, para la EPA ( Environmental Protection Agency). Esta licencia universal es un requisito por parte del Gobierno Federal, de conformidad con la Ley de Aire Limpio, que aprueba los técnicos para realizar los procedimientos de servicio y mantenimiento de sistemas de aire acondicionado y refrigeración. Recibirá prácticas de laboratorio en la recuperación, la presurización, y el manejo de los refrigerantes.
Modules
C-01 | Introduction | m03
In the Chapter 01: Introduction: The 05 lessons are shown below.
Lessons
C-02 | Core | m03
In the Chapter 02: Core: The 35 lessons are shown below.
Lessons
- S-01 || Stratospheric Ozone Degradation | m03-c02
- S-02 | Ozone Depletion Effects | m03-c02
- S-03 || Ozone Depletion Potential (ODP) | m03-c02
- S-04 | Types of Refrigerants According to Compound | m03-c02
- S-05 || CFC-”Chlorine Flourine and Carbon” | m03-c02
- S-06 || HCFC-”Hidrogen, Chlorine, Flourine and Carbon” | m03-c02-s06
- S-07 || HFC-”Hidrogen, Flourine and Carbon” | m03-c02
- S-08 || Refrigerant and Oils Substitutes | m03-c02
- S-09 | Refrigerant Mixture | m03-c02
- S-10 || Green House Effect | m03-c02
- S-11 || Detecting Leaks | m03-c02
- S-12 | Oils | m03-c02
- S-13 || Security in Refrigerants | m03-c02
- S-14 || The Montreal Protocol | m03-c02
- S-15 | Appliances Pressure Classification | m03-c02
- S-16 || Clean Air Act | m03-c02
- S-17 | Clean Air Act Enforcement | m03-c02
- S-18 || Section 608 Violations | m03-c02
- S-19 || Condition of Refrigerant in Each Component | m03-c02
- S-20 || Drying Filter | m03-c02
- S-21 || Test and Charging Manifold Gauges | m03-c02
- S-22 | Operational Positions for Refrigerant Manifold Gauges | m03-c02
- S-23 || Evacuation Process | m03-c02
- S-24 | Dehydration | m03-c02
- S-25 || The Electronic Vacuum Gauge | m03-c02
- S-26 | Safety | m03-c02
- S-27 | Pressure Measurements | m03-c02
- S-28 || The 3 “R’s ” | m03-c02
- S-29 || Recovery Devices | m03-c02
- S-30 | Disposable Cylinder | m03-c02
- S-31 | White Recovery Cylinders | m03-c02
- S-32 || Rechargeable Recovery Cylinder | m03-c02
- S-33 || Recovery Techniques | m03-c02
- S-34 | Risks of Filling Cylinders more than 80 % | m03-c02
- S-35 | Cylinder Transportation | m03-c02
C-03 | Type 1 | m03
In the Chapter 03: Type 1: The 16 lessons are shown below.
Lessons
- S-01 | Type I Intro | m03-c03
- S-02 || Type I Revison | m03-c03
- S-03 || Saturation Point | m03-c03
- S-04 | Pressure and Temperature Chart (T/P) | m03-c03
- S-05 || Piercing Valves | m03-c03
- S-06 | Low Loss Valves | m03-c03
- S-07 || Recovery and Recycled Requirements | m03-c03
- S-08 | Recovery Process | m03-c03
- S-09 | Recovery Techniques | m03-c03
- S-10 | Evacuation Process | m03-c03
- S-11 || Discovery of Acidity in the System | m03-c03
- S-12 || Leak Verification Process and Requirements | m03-c03
- S-13 | Acidity Test of the Refrigerant | m03-c03
- S-14 | Pressure and Temperature Comparison | m03-c03
- S-15 || Security Recommendations | m03-c03
- S-16 | Cylinder Transportation | m03-c03
C-04 | Type 2 | m03
In the Chapter 04: Type 2: The 20 lessons are shown below.
Lessons
- S-01 | Type II Revision | m03-c04
- S-02 || Service Valves or Three (3) Position Valves | m03-c04
- S-03 | Instruments and Components for Leak Detection | m03-c04
- S-04 || Nitrogen Regulator | m03-c04
- S-05 | Nitrogen Cylinder | m03-c04
- S-06 | Soap Solution to Detect Leaks | m03-c04
- S-07 || Electronic Leak Detector | m03-c04
- S-08 | R-22 Refrigerant | m03-c04
- S-09 || Red Fluorescent | m03-c04
- S-10 | Leak Detection Process | m03-c04
- S-11 || Leak Repair Requirements | m03-c04
- S-12 | The Recovery in Type II | m03-c04
- S-13 || Recovery Techniques and Requirements | m03-c04
- S-14 | The Recovery Process | m03-c04
- S-15 || Instruments and Components for Recovery | m03-c04
- S-16 | Loading Refrigerant into the System | m03-c04
- S-17 | Types of Repairs | m03-c04
- S-18 | Greater Repairs | m03-c04
- S-19 || Smaller Repairs | m03-c04
- S-20 | Recommendations | m03-c04
C-05 | Type 3 | m03
In the Chapter 05: Type 3: The 11 lessons are shown below.
Lessons
- S-01 | Type III Revision | m03-c05
- S-02 || Understanding Coolers | m03-c05
- S-03 | Purging Machine | m03-c05
- S-04 || Purging Units | m03-c05
- S-05 | Evaporator Charge Valve | m03-c05
- S-06 || Refrigerant Sight Glass | m03-c05
- S-07 | Removing Oil | m03-c05
- S-08 || Leak Detection | m03-c05
- S-09 | Leak Repair Requirements | m03-c05
- S-10 | Recovery Process | m03-c05
- S-11 | Recovery Requirements | m03-c05